Light, solar energy and thermal insulation values of the Şişecam coated glass we use in our façade projects. Daylight and solar energy values are given according to EN 410, and thermal transmittance (U value) according to EN 673.

Daylight Transmittance (%)The percentage of incident light that passes through the glass.
Solar Factor – g value (%)The percentage of solar heat energy entering the interior. A lower value means better solar control.
U Value (W/m²K)A measure of thermal insulation. A lower value means better thermal insulation.
Colour Rendering – Ra (%)How closely objects seen behind the glass match their true colours.

Low-E Glass (Thermal Control)

4+16+4 mm, coating on surface #3 (In double glazing, the coating can be on surface 2 or 3.)

← Scroll the table horizontally →

Low-E Glass (Thermal Control) performance values, 4+16+4 mm
ProductApplicationDaylight (EN 410)Colour Rendering %Solar Energy (EN 410)U Value W/m²K (EN 673)
Transmittance %External Reflectance %Internal Reflectance %Direct Transmittance %External Reflectance %Absorption %Solar Factor (g) %Shading CoefficientDry AirArgon
Şişecam ClimaxResidential buildings and small to medium-scale commercial projects where thermal control is the priority79121297532819610.701.41.1

Solar Low-E Glass (Thermal and Solar Control)

4+16+4 mm, coating on surface #2

← Scroll the table horizontally →

Solar Low-E Glass performance values, 4+16+4 mm
ProductApplicationDaylight (EN 410)Colour Rendering %Solar Energy (EN 410)U Value W/m²K (EN 673)
Transmittance %External Reflectance %Internal Reflectance %Direct Transmittance %External Reflectance %Absorption %Solar Factor (g) %Shading CoefficientDry AirArgon
Şişecam Climax SelectResidential buildings and small to medium-scale commercial projects that require air conditioning and where solar control and thermal insulation are wanted with a single coating72101297423028450.511.41.1

Temperable Low-E Glass (Thermal Control and Safety)(1)

4+16+4 mm, coating on surface #3

← Scroll the table horizontally →

Temperable Low-E Glass performance values, 4+16+4 mm
ProductApplicationDaylight (EN 410)Colour Rendering %Solar Energy (EN 410)U Value W/m²K (EN 673)
Transmittance %External Reflectance %Internal Reflectance %Direct Transmittance %External Reflectance %Absorption %Solar Factor (g) %Shading CoefficientDry AirArgon
Şişecam Climax T 80(2)Residential, school, hotel, hospital and similar projects, especially in cold climate regions, that require high light transmittance, thermal control, transparency and low reflectance79131497552718630.721.41.1
  • (1) The product must be used tempered in order to achieve the intended performance.
  • (2) Temperable and non-temperable options with the same colour and performance are available.

Temperable Low-E Glass (Thermal Control and Safety)(1)

6+16+6 mm, coating on surface #2

← Scroll the table horizontally →

Temperable Low-E Glass performance values, 6+16+6 mm
ProductApplicationDaylight (EN 410)Colour Rendering %Solar Energy (EN 410)U Value W/m²K (EN 673)
Transmittance %External Reflectance %Internal Reflectance %Direct Transmittance %External Reflectance %Absorption %Solar Factor (g) %Shading CoefficientDry AirArgon
Şişecam Climax T 71Residential, school, hotel, hospital and similar projects, especially in cold climate regions, that require high light transmittance, thermal control and maximum transparency72171596492328540.621.41.1
Şişecam Climax T 36 Smoke GreyProjects in hot climate regions and roof skylights that require controlled daylight transmittance and thermal and solar control3781393281161320.371.41.1
Şişecam Climax T 41 Bronze4291495291259340.391.41.1
  • (1) The product must be used tempered in order to achieve the intended performance.

Solar Low-E Glass (Thermal and Solar Control)

6+16+6 mm, coating on surface #2

← Scroll the table horizontally →

Solar Low-E Glass performance values, 6+16+6 mm
ProductApplicationDaylight (EN 410)Colour Rendering %Solar Energy (EN 410)U Value W/m²K (EN 673)
Transmittance %External Reflectance %Internal Reflectance %Direct Transmittance %External Reflectance %Absorption %Solar Factor (g) %Shading CoefficientDry AirArgon
Şişecam Duosol 70 One(2)(3)Boutique hotels, villas, shop windows and similar projects where the view is in the foreground and high light transmittance, effective thermal control, solar control, transparency and low reflectance are required71141494353727380.431.31.0
Şişecam Duosol 70(2)(3)Boutique hotels, villas and similar projects where the view is in the foreground and high light transmittance, thermal and solar control, transparency and low reflectance are required71111293382835410.471.41.1
Şişecam Duosol 50 One(2)(3)Office, hotel, hospital and similar projects that require optimum light transmittance for glare control and effective thermal and solar control49151494243342270.311.31.0
Şişecam Ecosol 62(2)(3)Residences, schools and similar projects that require high light transmittance and thermal and solar control depending on the glazing ratio of the façade64242096403426430.501.41.1
Şişecam Ecosol 50(2)(3)Office, hotel, hospital and similar projects that require optimum light transmittance for glare control, thermal control and effective solar control51332489313732340.391.41.1
  • (2) Temperable and non-temperable options with the same colour and performance are available.
  • (3) The coating is applied on Şişecam Extra Clear base glass.

Temperable Solar Low-E Glass (Thermal and Solar Control & Safety)(1)

6+16+6 mm, coating on surface #2

← Scroll the table horizontally →

Temperable Solar Low-E Glass performance values, 6+16+6 mm
ProductApplicationDaylight (EN 410)Colour Rendering %Solar Energy (EN 410)U Value W/m²K (EN 673)
Transmittance %External Reflectance %Internal Reflectance %Direct Transmittance %External Reflectance %Absorption %Solar Factor (g) %Shading CoefficientDry AirArgon
Şişecam Prosol T 60 One(3)Residences, schools, hotels and similar projects that require high light transmittance, effective thermal and solar control, transparency and low reflectance depending on the glazing ratio of the façade62141492273636290.331.31.0
Şişecam Duosol T 70 One(2)(3)Residences, boutique hotels, villas and similar projects that require high light transmittance, effective thermal control, solar control, transparency and low reflectance71131393353728370.431.31.0
Şişecam Duosol T 70(2)(3)Residences, boutique hotels, villas and similar projects that require high light transmittance, thermal and solar control, transparency and low reflectance71111294383032410.471.41.1
Şişecam Duosol T 58(3)Residences, schools and similar projects that require high light transmittance and thermal and solar control depending on the glazing ratio of the façade60191892303535320.371.41.1
Şişecam Duosol T 51(3)Office, hotel, hospital and similar projects that require optimum light transmittance for glare control, thermal control and effective solar control51241793263242290.331.41.1
Şişecam Duosol T 50 One(2)(3)Office, hotel, hospital and similar projects that require optimum light transmittance for glare control and effective thermal and solar control50161593243639270.311.31.0
Şişecam Duosol T 50Office, hotel, hospital and similar projects that require optimum light transmittance for glare control, thermal control and effective solar control49161889233245260.301.41.1
Şişecam Duosol T 40 One(3)Hot climate regions, roof skylights and similar projects that require controlled daylight transmittance and effective thermal and solar control41201489203644220.261.31.0
Şişecam Ecosol T 62(2)(3)Residences, schools and similar projects that require high light transmittance and thermal and solar control depending on the glazing ratio of the façade65242195403425430.501.41.1
Şişecam Ecosol T 31 Smoke GreyProjects in hot climate regions and roof skylights that require controlled daylight transmittance, thermal control and effective solar control33101992221563260.301.41.1
Şişecam Ecosol T 35 Bronze37111994231661270.311.41.1
Şişecam Ecosol T 50(2)(3)Office, hotel, hospital and similar projects that require optimum light transmittance for glare control, thermal control and effective solar control50322488303732330.381.41.1
Şişecam Ecosol T 28 Smoke GreyProjects in hot climate regions and roof skylights that require controlled daylight transmittance, thermal control and effective solar control25122285161668200.231.41.1
Şişecam Ecosol T 31 Bronze29142292171766210.241.41.1
Şişecam Ecosol T 43(3)Hot climate regions, roof skylights and similar projects that require controlled daylight transmittance, thermal control and effective solar control45352688264132290.331.41.1
Şişecam Ecosol T 21 Smoke GreyHot climate regions, roof skylights and similar projects that require controlled daylight transmittance, thermal control and effective solar control22122585141769180.211.41.1
Şişecam Ecosol T 24 Bronze26152592151867190.211.41.1
Şişecam Ecosol T 41Hot climate regions, roof skylights and similar projects that require controlled daylight transmittance, thermal control and effective solar control42333290253837280.321.41.1
Şişecam Ecosol T 40 Deep BlueHot climate regions, roof skylights and similar projects that require a blue colour effect provided by the coating, controlled daylight transmittance, thermal control and effective solar control38182492241760280.321.41.1
Şişecam Ecosol T 40 Deep GreenHot climate regions, roof skylights and similar projects that require a green colour effect provided by the coating, controlled daylight transmittance, thermal control and effective solar control40372795252649280.331.41.1
  • (1) The product must be used tempered in order to achieve the intended performance.
  • (2) Temperable and non-temperable options with the same colour and performance are available.
  • (3) The coating is applied on Şişecam Extra Clear base glass.

Reflective Glass (Solar Control)(4)

6+16+6 mm (reflective coating on surface #2, Şişecam Climax coating on surface #3)

← Scroll the table horizontally →

Reflective Glass (Solar Control) performance values, 6+16+6 mm
ProductDaylight (EN 410)Colour Rendering %Solar Energy (EN 410)U Value W/m²K (EN 673)
Transmittance %External Reflectance %Internal Reflectance %Direct Transmittance %External Reflectance %Absorption %Solar Factor (g) %Shading CoefficientDry AirArgon
Şişecam Tentesol Silver35293095253243310.361.41.1
Şişecam Tentesol Green28213092141373190.221.41.1
Şişecam Tentesol Blue21143086131275190.211.41.1
Şişecam Tentesol Smoke Grey18113095141472200.231.41.1
Şişecam Tentesol Bronze21133087151570210.241.41.1
Şişecam Tentesol Titanium Silver(5)59333098393625470.541.41.1
Şişecam Tentesol Titanium Green(5)47232988241462290.341.41.1
Şişecam Tentesol Titanium Blue(5)36162981221365280.321.41.1
Şişecam Tentesol Titanium Smoke Grey(5)30122994221663280.331.41.1
  • (4) Controls excessive sunlight by limiting solar heat gain into the building; used in commercial buildings such as hospitals, offices and shopping malls. Thanks to its reflective properties, it provides visual uniformity in curtain wall projects. Use as tempered or heat-strengthened glass is recommended.
  • (5) Due to the nature of the coating, the colour of the base glass is more noticeable.

The values are taken from the Şişecam “Glass solutions for façades” catalogue (2025) and are for information purposes only. Actual values may differ from those given depending on conditions at the place of use. Argon values in blue and bold indicate the lowest U value (1.0 W/m²K).